Step 1 | Pentalobe Screws

Step 1 image
  • As a preliminary precaution, ensure your iPhone's battery is depleted to a level below 25% prior to commencing the repair process.A fully charged lithium-ion batteryposes a significant fire and/or explosion hazard if it sustains accidental physical damage, such as a puncture.
  • Deactivate your iPhone by powering it down completely before you start disassembling it.
  • Using a suitable tool, extract the pair of 3.5 mm pentalobe screws located along the iPhone's lower edge.
  • Separating the iPhone's display assembly will inevitably damage the integrated waterproof seals; therefore, obtain replacement seals beforehand to prevent liquid ingress, or exercise extreme caution to avoid moisture exposure during reassembly if you choose not to replace the seals.

Step 2 | Mark your opening picks

Step 2 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
  • To avoid potential harm to your device, ensure the opening pick does not extend beyond its intended insertion depth; this procedure details how to identify a safe insertion point by marking the pick.
  • Determine the measurement of3 mmfrom the pick's leading edge and use a permanent marker to create a visible indicator on the opening pick.
  • For enhanced precision, consider marking additional points on the pick's corners, each representing a distinct measurement.
  • As another option, affix a coin to the pick's shaft,3 mmaway from its tip.

Step 3 | Tape over any cracks

Step 3 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
  • To minimize additional damage and potential injury while repairing a fractured iPhone display, secure the broken glass with adhesive tape.
  • Apply multiple layers of transparent packing tape across the iPhone's screen surface, ensuring complete coverage of the entire front face.
  • Always utilize eye protection, specifically safety glasses, to guard against glass fragments that may become dislodged during the repair process.
  • Should the suction cup fail to adhere properly during subsequent steps, create a handle by folding a robust tape, like duct tape, and employ it to gently raise the screen.
  • As a last resort, if other methods prove unsuccessful, consider using superglue to temporarily affix the suction cup to the display.

Step 4 | Anti-Clamp instructions

Step 4 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
  • The following three actions illustrate the function of the Anti-Clamp, a specialized tool developed to simplify the initial opening process; should you choose not to utilize this tool, proceed past these three steps for an alternative approach.
  • Detailed instructions regarding the Anti-Clamp's operation are available in a separate, dedicated guide.
  • Grasp theblue handleand move it in a rearward direction to disengage the Anti-Clamp's securing arms.
  • Carefully position the arms across either the left or right side of your iPhone.
  • Place the suction cups close to the lower edge of the iPhone, situated directly above the home button—one on the front face and one on the rear.
  • Apply pressure by compressing the cups together to create a vacuum seal on the intended surface.
  • Should the iPhone's surface prove too smooth for the Anti-Clamp to maintain a secure hold, applying adhesive tape can generate a more textured area for improved grip.

Step 5

Step 5 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
  • To secure the arms, advance the blue handle in its direction.
  • Rotate the handle a full 360 degrees, or continue until the suction cups exhibit signs of deformation.
  • Maintain the parallel positioning of the suction cups; should they deviate from their alignment, a minor adjustment of the arms, achieved by slightly releasing the suction cups, is necessary to restore proper positioning.

Step 6

Step 6 image
Thumbnail 1
Thumbnail 2
Procedure Six:
  • Employing an iOpener, apply heat and guide it through the arms of the Anti-Clamp; alternative heating methods such as a hair dryer, heat gun, or hot plate are permissible, however, exercise caution as excessive temperatures may compromise the display or internal battery.
  • Position the iOpener so that it rests along the lower edge of the iPhone’s casing.
  • Allow a sixty-second interval to permit the adhesive to loosen and establish a separation.
  • Once the Anti-Clamp generates a substantial opening, introduce an opening pick beneath the display’s surface.
  • Should the Anti-Clamp fail to produce an adequate gap, increase the heat applied to the region and rotate the handle by ninety degrees.
  • Avoid incremental handle rotations exceeding ninety degrees, and incorporate sixty-second pauses between each rotation; allow the Anti-Clamp and time to facilitate the separation process.
  • Omit the subsequent three steps.

Step 7

Step 7 image
Phase Seven:
The subsequent three procedures detail the display detachment process, employing a suction device.
Applying heat to the iPhone's bottom border will facilitate the loosening of the adhesive bonds holding the screen in place, simplifying the separation.
Employ a hairdryer or utilize an iOpener, directing heat to the lower edge of the iPhone for approximately 90 seconds to reduce the adhesive's tackiness.

Step 8

Step 8 image
Thumbnail 1
Thumbnail 2
Proceed to step 8:
Secure a suction cup to the bottom portion of the front panel, positioned directly over the home button's area.
Ensure the suction cup's surface area remains clear of the home button itself, because contact will obstruct the creation of a proper bond between the suction device and the glass.

Step 9

Step 9 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
Procedure Nine:
  • Applying steady, consistent force to the suction cup will lift the front panel, generating a small separation from the rear case assembly.
  • Introduce an opening tool, or a similarly slender prying implement, into the newly formed space, inserting it approximately a few millimeters.
  • Due to the robust nature of the waterproof adhesive securing the display, establishing this initial separation requires considerable force; should you encounter difficulty, applying additional heat and gently oscillating the screen in an upward and downward motion can reduce the adhesive's strength, facilitating the creation of a sufficient gap for tool insertion.

Step 10

Step 10 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
Procedure 10:
  • Utilizing a specialized tool, carefully maneuver it along the perimeter, ascending the left side of the device's exterior, progressing in the direction of the volume adjustment controls and the mute switch, to sever the adhesive bonds securing the display assembly.
  • Cease movement in the vicinity of the upper-left corner of the display panel.

Step 11 | Screen information

Step 11 image
Phase 11:

A fragile wiring harness is situated on the right-hand side of the iPhone; avoid inserting any tools in this area to prevent potential cable damage.

Step 12

Step 12 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
Procedure 12:
  • Position your tool once more at the lower-right section of the iPhone, then maneuver it along the corner and upward along the right edge to release the adhesive bond.
  • Ensure the tool's insertion depth remains under 3 millimeters to prevent potential harm to the display cable connections.

Step 13

Step 13 image
  • Carefully elevate the display's lower border by applying upward force to the suction cup.
  • Avoid lifting the display beyond an angle of15 degreesas exceeding this limit could potentially damage or sever the flexible cable assemblies that link the display to the device's internal components.

Step 14

Step 14 image
  • To detach the suction cup from the front panel, grasp and exert force on the small protrusion located on its surface.

Step 15

Step 15 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
  • Carefully insert a prying tool beneath the screen's upper edge, working along the top to release the remaining adhesive securing the display.

Step 16

Step 16 image
Thumbnail 1
Thumbnail 2
  • To release the retaining clips securing the display assembly to the rear case, carefully move the display downwards, shifting it away from the phone's upper border.

Step 17

Step 17 image
Thumbnail 1
Thumbnail 2
Thumbnail 3

To access the internal components, initiate the display opening process by pivoting the screen upwards from the left edge, mimicking the action of opening a book's cover.
Refrain from completely disconnecting the display assembly at this stage, because multiple delicate ribbon cables remain attached, linking it to the iPhone's main circuit board.
Secure the display in an upright position using a support to prevent it from obstructing your work area during the repair.

Step 18 | Battery Disconnection

Step 18 image
Thumbnail 1
Thumbnail 2

Detach the four Phillips (JIS) screws that fasten the lower display cable bracket to the logic board; these screws have the following dimensions:

  • Two 1.3 mm screws
  • One 1.4 mm screw
  • One 2.7 mm screw

During the repair process, meticulously organize and track all screws to ensure correct placement during reassembly, as improper screw installation can result in irreversible component damage.

Step 19

Step 19 image

Detach the securing bracket that holds the lower display cable in place.

Step 20

Step 20 image
Thumbnail 1
Thumbnail 2

Employ the tip of a spudgerto carefully lift the battery connector away from its corresponding receptacle on the logic board.
Gently elevate the connector cable a small amount to ensure it remains disconnected from the socket, thus avoiding unintended power delivery to the device during the repair process.

Step 21 | Display Assembly

Step 21 image
Thumbnail 1
Thumbnail 2
  • Employ the pointed end of a spudger or a fingernail to release the large lower display connector, lifting it vertically away from its receptacle.
  • When re-engaging connectors, apply pressure to one lateral edge until a secure connection is achieved, then repeat the process on the opposing side; avoid applying force to the central portion. Even minor misalignment during reattachment can result in connector deformation and irreversible harm.

Step 22

Step 22 image
Thumbnail 1
Thumbnail 2
To proceed, detach the connector for the second lower display cable, which is situated immediately behind the connector previously removed.

Step 23

Step 23 image
Thumbnail 1
Thumbnail 2
  • Detach the bracket that covers the connector for the front panel sensor assembly by unscrewing two tri-point screws.Y000These screws consist of one measuring 1.0 millimeters and another measuring 1.2 millimeters.
    One 1.0 mm screw
    One 1.2 mm screw

Step 24

Step 24 image
Disconnect the protective cover that shields the electrical connector for the front panel sensor assembly.

Step 25

Step 25 image
Thumbnail 1
Thumbnail 2
Employ the pointed end of a spudger, or a fingernailto carefully separate the front panel sensor assembly connector from its corresponding receptacle.This action ensures a clean disconnection.

Step 26

Step 26 image
  • Detach the display unit from the device.
  • When putting the device back together, halt at this point should you decide to substitute the adhesive that seals the display's perimeter.

Step 27 | Earpiece Speaker

Step 27 image
  • To detach the earpiece speaker bracket, begin by eliminating the five fasteners.These fasteners consist of Phillips head screws.The bracket is held in place by these screws.
    • Two screws, each measuring 1.8 millimeters in diameter, are included.
    • A single screw with a 2.3-millimeter diameter is also present.
    • Additionally, a screw with a 2.4-millimeter diameter is required.
    • Finally, a 2.8-millimeter screw completes the set.

Step 28

Step 28 image
  • Detach the securing bracket that holds the earpiece speaker in place.

Step 29

Step 29 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
  • Employ the planar edge of a spudger to disengage the front-facing camera assembly from its mounting.spudgerCarefully flex the camera's flexible circuit cable laterally to provide access to the earpiece speaker located directly beneath it.
  • Gently bend the camera ribbon cable to the side to clear the way to the earpiece speaker underneath.

Step 30

Step 30 image
  • Carefully detach the earpiece speaker component.

Step 31 | Front Camera and Sensor Cable

Step 31 image
Thumbnail 1
Thumbnail 2
  • Carefully maneuver the camera assembly and its connected ribbon cable downwards within the iPhone's internal structure, creating space to reach the underlying parts.

Step 32

Step 32 image
  • To loosen the adhesive that holds the sensors in place, apply heat using a hairdryer or heat gun, or utilize an iOpener, directing it to the front upper portion of the display for approximately one minute.
  • Thesensorsinvolved in the subsequent procedures are delicate; consistently applying additional heat as required will improve the likelihood of successful removal without causing harm. As an alternative, introducing a small amount of isopropyl alcohol, allowing it to seep beneath the sensors, can facilitate their separation before prying.

Step 33

Step 33 image
Thumbnail 1
Thumbnail 2
  • Carefully insert a spudger beneath the flexible cable connected to the ambient light sensor, and gently raise the sensor assembly from its enclosure.

Step 34

Step 34 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
  • Carefully insert the pointed end of a spudgerspudgerbeneath the proximity sensor flex cable, then gently raise the sensor assembly from its enclosure.

Step 35

Step 35 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
  • Position the pointed end of aiFixit opening toolbeneath the flex cable connecting the camera module, located on the side opposite the front camera.
    Employ aniOpeneror a hairdryer, applying heat as necessary to the upper section of the display, which will help to loosen the adhesive holding the flex cable in place.
    Apply gentle lifting force to disengage the flex cable's edge from the display's rear surface.

Step 36

Step 36 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
  1. Employ the tip of a spudger to carefully introduce it beneath the flex cable section previously detached.spudgerProceed with disengaging the remaining portion of the flex cable, utilizing the spudger to gently slide underneath the circular array of gold earpiece speaker contacts.
  2. Continue separating the remainder of the flex cable, pushing the spudger underneath the row of circular gold earpiece speaker contacts.

Step 37

Step 37 image
Thumbnail 1
Thumbnail 2
Thumbnail 3
  • Disconnect the front camera and sensor cable assembly from the device.
  • A segment of black double-sided insulating tape is present.This tape is positioned between the display panel and the three parallel lines of copper contacts located on the rear side of the camera/sensor cable; it might adhere to the display or detach with the cable itself.
    During reassembly procedures, confirm theinsulating tape's presenceto ensure proper functionality, or alternatively, apply a suitable substitute tape, like Kapton tape, to shield the contacts on the cable's rear surface.